MONITORING DATA QUALITY

Geotechnical Monitoring Data QA/QC

Build defensible monitoring data through consistent field records, baseline control, validation checks, anomaly investigation and traceable engineering review.

OVERVIEW

Reliable decisions require trustworthy observations

A chart can look smooth and still contain engineering-significant errors.

Geotechnical monitoring data QA/QC is the set of preventive controls and detection checks that help ensure field measurements are complete, correctly attributed, comparable and fit for engineering interpretation.

Quality assurance (QA) is mainly about designing procedures that prevent errors; quality control (QC) checks detect problems after or during acquisition. USGS describes this distinction in its data-quality guidance.

Across inclinometer, groundwater, settlement, strain and vibration monitoring, the objective is not to hide outliers. It is to preserve the original observations while making errors, uncertainty and engineering review decisions clear.

FRAMEWORK

A four-stage monitoring quality framework

Quality should be built into the entire data lifecycle.

PreventInstrument ID register, installation record, survey datum, calibration and collection method.
ValidateUnits, timestamps, completeness, physical range, sequence and duplicates.
InvestigateCheck stage of works, independent sensor evidence and field conditions.
DocumentRaw/derived records, reason codes, reviewer decision and revision trail.

CHECKS

Checks that catch common failures

Each check should produce a reviewable result, not silently alter the source data.

Check Potential failure Recommended response
Identity & provenance Reading assigned to wrong instrument or depth Cross-check sensor register, location, installation zone and device ID.
Time & frequency Timezone conversion, clock drift, unexpected gap Record source timezone and resynchronisation; distinguish missing data from zero.
Units & sign mm vs m, pressure vs head, positive vs negative Use an approved measurement dictionary and explicit conversion rules.
Baseline & datum Changed baseline, reference point movement Freeze original baseline history; record surveys and approved changes.
Plausibility & rates Spikes, flatlines, unrealistic step changes Flag, compare raw signal and installation information; investigate field work.
Cross-source consistency Settlement, wall displacement and groundwater disagree Compare expected mechanisms and construction stages; do not assume correlation proves causation.
Calibration & maintenance Drift, failed sensor, replacement Record maintenance event, calibration evidence, instrument status and any adjusted series.

EXCEPTIONS

Outliers are questions—not automatic deletions

Separate signal faults from legitimate engineering events.

Suspect measurement

Verify raw signal, logger status, wiring, power, survey reference and recently changed metadata.

Genuine transient

Preserve the event and its timing; align it with construction operations, weather or other external influence.

Data correction

Retain source value, revised value, reason code, method, author and timestamp; make the change reversible.

Engineering escalation

Use the approved trigger/action plan and responsible engineer’s judgment when confirmed observations may indicate risk.

GOVERNANCE

Traceability from sensor to report

Trust is built by a reproducible chain of transformations.

A defensible data record should identify what was observed, where, when, by which instrument and method, with what unit and calibration, and how it was transformed into a reported quantity.

For a mature monitoring workflow, source records remain immutable or separately preserved. Derived data, quality flags, acceptance decisions, plots and reports are versioned, so a reviewer can reconstruct an assessment.

GEOOE’s engineering-intelligence work explores field-to-review workflows and specialist monitoring data methods. Learn more about Engineering Intelligence and data interoperability.

FAQ

Monitoring QA/QC FAQs

Practical distinctions for owners, engineers and monitoring contractors.

Is an automated alert the same as a validated exceedance?
No. Automated screening identifies a condition requiring action under the project procedure; verification and engineering interpretation remain necessary.
Should questionable readings be deleted?
Retain raw data and clearly record the disposition. A flagged measurement can be excluded from a derived assessment only with documented justification.
Does AI replace an engineer in monitoring data QA/QC?
No. AI can assist with screening and report workflows, but its output must be validated against instrumentation, design and site context.

REFERENCES

Data quality and metadata standards

Public guidance that informs the workflow above.

  1. U.S. Geological Survey — Manage Quality: QA and QC
  2. U.S. Geological Survey — Metadata Creation
  3. Open Geospatial Consortium — SensorThings API Standard